SECTION 2 - INSTALLATION
WARNING
Do not obstruct the flow of combustion and ventilation air to and from your oven.  There must be no
obstructions around or underneath the oven.  Constructional changes to the area where the oven is
installed shall not affect the air supply to the oven.
NOTE
There must be adequate clearance between the oven and combustible construction.  Clearance
must also be provided for servicing and for proper operation.
NOTE
An electrical wiring diagram for the oven is located inside the machinery compartment.
NOTE
All aspects of the oven installation, including placement, utility connections, and ventilation requirements,
must conform with any applicable local, national, or international codes.  These codes supercede the require-
ments and guidelines provided in this manual.
WARNING
The oven must be installed on an even (level) non-flammable flooring and any adjacent walls must be non-
flammable.  Recommended minimum clearances are specified in the Description section of this Manual.
WARNING - 
After any conversions, readjustments, or service work on the oven:
•
Perform a gas leak test.
•
Test for correct air supply, particularly to the burner blower.
•
Test for proper combustion and gas supply.
•
Check that the ventilation system is in operation.
Table 1-3:  Electrical specifications (per oven cavity)
Main  Blower
Control
Current
Oven  Model
  Voltage
Circuit  Voltage
Phase
Freq.
Draw  *
Poles
Wires
Gas  Ovens
220-230V
120V  (transformer)
1 Ph
50 Hz
8A
2 Pole
3 Wire (1 hot, 1 neut, 1 gnd)
Electric Ovens
380-400V
120V  (transformer)
1 Ph
50 Hz
39A
2 Pole
5 Wire (3 hot, 1 neut, 1 gnd)
* CAUTION:  The current draw shown in the chart above is an average value for normal operation.  The initial amperage draw on oven startup
may exceed the listed value.
IMPORTANT:  Additional electrical information is provided on the oven's serial plate, and on the wiring diagram inside the machinery compartment.
Table 1-4:  Gas orifice and pressure specifications (per oven cavity)
Supply (inlet) Pressure (mbar)
IE,IT,
AT,CH,
Orifice
Main
Pilot
Bypass
PT,ES,
DK,FI, (manifold) Rated
Orifice
Orifice
Orifice
GB
DE
NL
BE,FR
SE
pressure
Heat
Supply
Gas
Gas Type
dia.
dia.
dia.
II
2H3+
II
2ELL3B/P
II
2L3B/P
II
2E+3+
II
2H3B/P
(mbar)
Input
Volume
Flow
PS360U, PS360L
Natural,  G20
5.50mm
0.635mm
1.65mm
20
20
--
20-25
20
6.8
40kw
4.2m
3
h
70.0 
l
/min
Natural,  G25
5.50mm
0.635mm
1.65mm
--
20
25
--
--
10.5
40kw
4.2m
3
h
81.7 
l
/min
Natural,  G20,  G25
4.50mm
0.635mm
1.50mm
20
20
25
20-25
20
6.8-10.5
40kw 4.2-4.9m
3
h
70.0-81.7 
l
/min
Liquid,  G30
2.70mm
0.381mm
0.85mm
29-37
--
28-30
29-37
50
*
40kw
3.1kg/h
--
Liquid,  G30,  G31
3.10mm
0.381mm
0.95mm
--
50
30
--
50
*
40kw
3.1kg/h
--
PS360WB-U, PS360WB-L
Natural,  G20
6.30mm
0.635mm
2.30mm
20
20
--
20-25
20
6.8
50kw
5.3m
3
h
88.0 
l
/min
Natural,  G25
6.30mm
0.635mm
2.30mm
--
20
25
--
--
10.5
50kw
6.1m
3
h
102.4 
l
/min
Natural,  G20,  G25
5.40mm
0.635mm
2.00mm
20
20
25
20-25
20
6.8-10.5
50kw 5.3-6.1m
3
h 88.0-102.4 
l
/min
Liquid,  G30
3.10mm
0.381mm
1.40mm
29-37
--
28-30
29-37
50
*
50kw
3.9kg/h
--
Liquid,  G30,  G31
3.50mm
0.381mm
1.40mm
--
50
30
--
50
*
50kw
3.9kg/h
--
*  Pressure regulator (governor) not in operation, system at supply (inlet) pressure.
Orifice pressures apply to 15°C, 1.013mbar dry gas.
WARNING
Keep the appliance area free and clear of combustibles.