B. Recommendations
NOTE THAT THE HOOD DIMENSIONS SHOWN IN FIGURE 2
ARE RECOMMENDATIONS ONLY.  LOCAL, NATIONAL, AND
INTERNATIONAL  CODES  MUST  BE  FOLLOWED  WHEN
INSTALLING THE VENTILATION SYSTEM.  ANY APPLICABLE
LOCAL  AND  NATIONAL  CODES  SUPERSEDE  THE
RECOMMENDATIONS SHOWN IN THIS MANUAL.
The rate of air flow exhausted through the ventilation system
may vary depending on the oven configuration and hood design.
Consult the hood manufacturer or ventilation engineer for these
specifications.
To  avoid  a  negative  pressure  condition  in  the  kitchen  area,
return air must be brought back to replenish the air that was
exhausted.  A negative pressure in the kitchen can cause heat-
related problems to the oven components as if there were no
ventilation  at  all.    The  best  method  of  supplying  return  air  is
through  the  heating,  ventilation  and  air  conditioning  (HVAC)
system.  Through the HVAC system, the air can be temperature-
controlled  for  summer  and  winter.    Return  air  can  also  be
brought  in  directly  from  outside  the  building,  but  detrimental
effects  can  result  from  extreme  seasonal  hot  and  cold
temperatures  from  the  outdoors.
NOTE: Return air from the mechanically driven system must not
blow at the opening of the baking chamber.  Poor oven baking
performance will result.
C. Other ventilation concerns
•
Special locations, conditions, or problems may require the
services of a ventilation engineer or specialist.
•
Inadequate ventilation can inhibit oven performance.
•
It  is  recommended  that  the  ventilation  system  and  duct
work be checked at prevailing intervals as specified by the
hood manufacturer and/or HVAC engineer or specialist.
A. Requirements
CAUTION
CAUTION
Gas  oven  installations  REQUIRE  a  mechanically  driven
ventilation system with electrical exhaust air sensing control.
A  mechanically  driven  ventilation  system  is  STRONGLY
RECOMMENDED for electric oven installations.
PROPER  VENTILATION  OF  THE  OVEN  IS  THE
RESPONSIBILITY  OF  THE  OWNER.
II. VENTILATION SYSTEM
IMPORTANT
Where national or local codes require the
installation of fire suppression equip-
ment or other supplementary equipment,
DO NOT mount the equipment directly to
the oven.
MOUNTING SUCH EQUIPMENT ON
THE OVEN MAY:
• VOID  AGENCY  CERTIFICATIONS
• RESTRICT  SERVICE  ACCESS
• LEAD  TO  INCREASED  SERVICE
EXPENSES FOR THE OWNER
Fig. 2-2 - Ventilation System
458mm
SECTION 2 - INSTALLATION