Installation 
18
309293J
Check Electrical Grounding
1.
Have a qualified electrician check the electrical 
grounding continuity of the spray gun and air hose.
2.
Turn the ES ON/OFF valve OFF. 
3.
Turn off the air and fluid supply to the gun. The fluid 
hose must not have any fluid in it.
4.
Make sure the red-colored grounded air hose (R) is 
connected and the hose ground wire is connected to 
a true earth ground.
5.
Using an ohmmeter (AA), measure the resistance 
between the gun handle (BB) and a true earth 
ground (CC). The resistance should not exceed 100 
ohms. See F
6.
If the resistance is greater than 100 ohms, check the 
tightness of the ground connections and be sure the 
air hose ground wire is connected to a true earth 
ground. If the resistance is still too high, replace the 
air hose.
Fig. 13. Check Gun Grounding
7.
Using an ohmmeter (AA), measure the resistance 
between the cabinet ground lug (214) and a true 
earth ground (CC). See F
. 14.. The resistance 
must be less than 100 ohms.
Fig. 14.  Check Cabinet Grounding
I                          O
ES
ti1273a
ti1259a
AA
BB
CC
TI2161A
TI2163A
AA
214
CC