Elica ETT136SS 사용자 매뉴얼

다운로드
페이지 32
8
2.  Using 2 or more people, hang the range hood on the the wall 
 
by placing the slotted holes in the range hood back over the 2 
 
screws mounted to the wood support mounted to the wall. 
NOTE: If your installation uses the optional duct cover, the vent sys-
tem needs to be connected to the hood and the duct cover mounted 
to the top of the range hood before tightening the mounting screws. 
21¼” (54cm)
A
C
C
B
Rear View
A. Key hole slots
B. Security lower key holes (2 - 6 x 80 mm)
C. Security key holes (4 - 4.2 x 19 mm)
D. Knockouts
A
C
C
B
D
3.  Adjust depth of original mounting screws in the wood support until 
 
they protrude 
1
4
”  forward. This 
1
4
” gap will provide clearance to 
 
hang the hood (A).
4.  Push the range hood up into the narrow slots, align the bottom of 
 
the hood to the horizontal line, level the hood, and tighten the 2 
 
mounting screws.
5.  Mark 2 lower mounting hole locations. Drill 
1
8
” pilot holes if the 
 
holes are located into wood. If holes are not located into wood, 
 
remove the hood and drill two 
3
8
” pilot holes and insert 10 x 50 
 
mm wall anchors. Remount the hood, level, and tighten the upper 
 
screws. Install 2 - 6 x 80 mm screws and 2 - flat washers into the 
 
lower mounting anchors and tighten (B).
6.  Install 4 - 4.2 x 19 mm screws through the back of the hood 
 
into the wood support and tighten (C).
7.  Connect vent system to hood. Seal all joints with clamps.
8.  If your installation uses the optional duct cover, mount it to 
 
the top of the range hood following the instructions supplied 
 
with the duct cover. 
 
Make Electrical Connection
 
 
WARNING: Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating. 
Failure to do so can result in death or electrical shock. 
1.  Disconnect power.
2.  Locate junction box inside of the range hood.
A
A. Knockout in canopy back into terminal box
E
A
B
C
D
F
A.White wires
B. Black wires
C. UL listed wire connectors
D. Green, Bare or Yellow/Green wires
E. Home power supply
F. UL listed or CSA approved ½” strain    
 relief
3.  Use UL listed wire connectors and connect black wires (B) 
 together.
4.  Use UL listed wire connectors and connect white wires (A) 
 together.
5.  Connect green (or bare) ground wire from home power supply 
 
to the green/yellow ground wire (D) in terminal box using UL 
 
listed wire connectors.
6.  Install terminal box cover.
7.  Check that all light bulbs are secure in their sockets.
8.  Reconnect power.