Elica ETT136SS 사용자 매뉴얼

다운로드
페이지 32
7
Installation
 
•  If possible, disconnect and move freestanding or slide-in range 
 
from cabinet opening to provide easier access to rear wall.  
 
Otherwise put a thick, protective covering over countertop,  
 
cooktop or range to protect from damage and debris. Select a flat 
 
surface for assembling the unit. Cover that surface with a  
 
protective covering and place all canopy hood parts and hardware in it.
•  Determine and mark the centerline on the wall where the canopy 
 
hood will be installed.
•  Select a mounting height between a minimum of 18” (45.72 cm) 
 
and a suggested maximum of 24” (61 cm), above the cooking 
 
surface and the bottom of the range hood and mark a horizontal 
 
reference line on the wall.
•  Remove the wood support from the back of the range hood 
 
by loosening the 2 screws from the inside. Locate and level  
 
the top of the wood support 15
3
8
” (39.1 cm) above the marked 
 
horizontal line and centered on the vertical centerline. 
 
Using 2 - 6 x 80 mm screws, install wood support so that it is 
 
screwed into at least 2 vertical studs. 
Wood 
support
15
3
8
18”
to
24”
Centerline
of installation 
space
NOTE: The screws provided for mounting this hood must be 
fastened into solid wood, do not fasten into sheet rock only. 
Installing the Duct Cover Kits
 
Attach the full-width duct cover to the top of the range hood with the 
screws provided with duct covers. The duct cover must be attached to 
the top of the range hood before mounting the range hood to the wall. 
For information on ordering the optional duct cover, see “Optional 
Accessories” section. 
Complete preparation
 
1.  Determine and make all necessary cuts in the wall for the vent 
 
system. Install the vent system before installing the range hood. 
 
See the “Venting Requirements” section.
2.  Determine the location where the power supply cable will be run 
 
through the wall.
3.  Drill a 1¼” (3.2 cm) hole at this location.
4.  Pull enough power supply cable through the wall to allow for easy 
 
connection to the terminal box.
5.  Install the 10” (25.4 cm) square x 10” (25.4 cm) round vent 
 
transition with damper to top of the range hood using  
 
4 - 3.5 x 9.5 mm screws. 
6.  Remove terminal box cover and set aside.
7.  Remove knockout from the top of the vent hood and install a UL 
 
listed or CSA approved ½” strain relief. See “Make Electrical 
 
Connection” section.
8.  Place the range hood near its mounting position and run the 
 
power supply cable through the strain relief into terminal box 
 
(enough to make connection).
9.  Tighten the strain relief screws. 
 
Install Range Hood
The hood attaches to the wall by the 2 mounting screws in the
wood support mounted to the wall.
1.  Remove metal grease filters. See the “Range Hood Care” 
 section. 
 
 
NOTE: Only for the ETT142SS model, remove the lateral 
 
panels as shown the picture below.