6.12 Device Clock Table
This section provides the timing requirements and switching characteristics for the various clock options
available on the F2812 DSP.
lists the cycle times of various clocks.
Table 6-3. Clock Table and Nomenclature
MIN
NOM
MAX
UNIT
t
c(OSC)
, Cycle time
28.6
50
ns
On-chip oscillator clock
Frequency
20
35
MHz
t
c(CI)
, Cycle time
6.67
250
ns
XCLKIN
Frequency
4
150
MHz
t
c(SCO)
, Cycle time
6.67
500
ns
SYSCLKOUT
Frequency
2
150
MHz
t
c(XCO)
, Cycle time
6.67
2000
ns
XCLKOUT
Frequency
0.5
150
MHz
t
c(HCO)
, Cycle time
6.67
13.3
(1)
ns
HSPCLK
Frequency
75
(1)
150
MHz
t
c(LCO)
, Cycle time
13.3
26.6
(1)
ns
LSPCLK
Frequency
37.5
(1)
75
MHz
t
c(ADCCLK)
, Cycle time
(2)
40
ns
ADC clock
Frequency
25
MHz
t
c(SPC)
, Cycle time
50
ns
SPI clock
Frequency
20
MHz
t
c(CKG)
, Cycle time
50
ns
McBSP
Frequency
20
MHz
t
c(XTIM)
, Cycle time
6.67
ns
XTIMCLK
Frequency
150
MHz
(1)
This is the default reset value if SYSCLKOUT = 150 MHz.
(2)
The maximum value for ADCCLK frequency is 25 MHz. For SYSCLKOUT values of 25 MHz or lower, ADCCLK has to be
SYSCLKOUT/2 or lower. ADCCLK = SYSCLKOUT is not a valid mode for any value of SYSCLKOUT.
6.13 Clock Requirements and Characteristics
6.13.1 Input Clock Requirements
The clock provided at the XCLKIN pin generates the internal CPU clock cycle.
Table 6-4. Input Clock Frequency
(1)
PARAMETER
MIN
TYP
MAX
UNIT
Resonator
(2)
20
35
f
x
Input clock frequency
Crystal
(2)
20
35
MHz
XCLKIN
4
150
f
l
Limp mode clock frequency
2
MHz
(1)
Not production tested.
(2)
Not guaranteed for T
A
> 125°C.
94
Electrical Specifications
Copyright © 2009–2010, Texas Instruments Incorporated
Product Folder Link(s):