IBM 21Y Manual Do Utilizador

Página de 210
20
Netfinity 3500-M20 – Type 8657 Models 21Y, 22Y, 31Y, 32Y,
Ethernet controller messages
The integrated Ethernet controller might display messages 
from the following device drivers:   
Novell™ NetWare™ or IntraNetWare Server ODI
NDIS Adapter for level 2.01 (OS/2)
NDIS Adapter for level 4.0 (Windows NT)
SCO™ UNIX LLI
Novell NetWare or IntraNetWare server ODI 
driver messages
This section provides explanations of the error messages for 
the Novell NetWare or IntraNetWare server ODI driver, and 
suggested actions to resolve each problem.
The Ethernet 
controller 
stopped 
working 
when 
another 
adapter was 
added to the 
server.
Check the following:   
Make sure that the cable is 
connected to the Ethernet controller.
Make sure that the PCI system BIOS 
is current.
Reseat the adapter.
Determine if the interrupt (IRQ) 
setting assigned to the Ethernet 
adapter is also assigned to another 
device in the Configuration/Setup 
Utility program.   
Although interrupt sharing is allowed 
for PCI devices, some devices do not 
function well when they share an 
interrupt with a dissimilar PCI device.  
Try changing the IRQ assigned to the 
Ethernet adapter or the other device.
The Ethernet 
controller 
stopped 
working 
without 
apparent 
cause.
Check the following:   
Run diagnostics for the Ethernet 
controller.
Try a different connector on the hub.
Reinstall the device drivers.  Refer to 
the operating-system documentation 
and to the ServerGuide information.
Table 1. Ethernet troubleshooting chart 
Ethernet 
controller 
problem
Suggested Action