NW-072
A resource tag is unavailable.   
Explanation:  The driver tried to allocate 
some resources that were not available.   
Action:  Add more memory, or free some 
memory resources in the server.  Then, 
restart the server.
PCNTNW-
NW-073
Unable to allocate memory 
Explanation:  The driver failed to allocate 
the memory needed for normal operation.   
Action:  Add more memory, or free some 
memory resources in the server.  Then, 
restart the server.  
PCNTNW-
NW-074
The hardware interrupt cannot be set. 
Explanation:  An attempt was made to 
initialize a given hardware interrupt.  The 
attempt was not successful.  
Action:  Verify that the Ethernet controller 
is enabled.  If the Ethernet controller is 
enabled, go to “Starting the diagnostic 
programs” on page 11 to
 run the 
diagnostic programs.  If you have an 
Ethernet adapter installed, make sure that 
the adapter does not share an IRQ with 
any other device.
PCNTNW-
NW-075
The Multiple Link Interface Driver 
(MLID) cannot be registered with the 
Link Support Layer (LSL).
 
Explanation:  An error occurred while the 
driver was trying to register with the LSL.  
Action:  Check the version of the 
NetWare or IntraNetWare Operating 
System.  Make sure that this driver is 
correct for the version of NetWare or 
IntraNetWare that you are using.  Restart 
the server.
PCNTNW-
NW-079
The Multiple Link Interface Driver 
(MLID) did not initialize MSMTx Free 
Count.
 
Explanation:   The MSMTx Free Count is 
not initialized correctly. 
Action:  Restart the server.  If the problem 
persists,  go to “Starting the diagnostic 
programs” on page 11 to
 run the 
diagnostic programs.
Table 2. Novell NetWare or IntraNetWare ODI driver 