 Diagnostics
 
21
Table 2. Novell NetWare or IntraNetWare ODI driver 
messages for the Ethernet controller 
PCNTNW-
NW-026
The MSM is unable to parse a required 
custom keyword.
 
Explanation:  The user entered an 
incorrect parameter keyword.  
Action:  Reload the driver using the 
correct keyword.
PCNTNW-
NW-054
The adapter did not respond to the 
initialization command.
 
Explanation:  The adapter did not 
respond when the driver tried to initialize 
it.   
Action:  Verify that the Ethernet controller 
is enabled.  If the Ethernet controller is 
enabled, go to “Starting the diagnostic 
programs” on page 11 to
 run the 
diagnostic programs.
PCNTNW-
NW-058
The adapter did not respond to the 
initialization command.
 
Explanation:  The interrupt request (IRQ) 
setting might not be valid or the EEPROM 
information might be incorrect.  
Action:  Make sure the IRQ settings are 
correct in the Configuration/Setup Utility 
program.  for information on setting the 
interrupt requests.  If the IRQ settings are 
correct,  go to “Starting the diagnostic 
programs” on page 11 to
 run the 
diagnostic programs.
PCNTNW-
NW-066
The cable might be disconnected from 
the adapter.
 
Explanation:  The cable might be 
disconnected from the server Ethernet 
port.  
Action:  Verify that a cable is connected 
to the Ethernet port.
PCNTNW-
NW-071
The matching virtual adapter could not 
be found.
 
Explanation:  You tried to load another 
instance of the driver with a different I/O 
address.  This new adapter could not be 
found.  
Action:  Verify that you installed an IBM 
Netfinity 10/100 Fault Tolerant Adapter 
and make sure that the adapter is seated 
correctly.  If the adapter is seated 
correctly,  go to “Starting the diagnostic 
programs” on page 11 to
 run the 
diagnostic programs.