DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-732
DUPINT (Duplication Interface Circuit Pack) 
9
the active and standby SPEs. After testing of DUPINT is complete, the command 
release spe must be entered before memory shadowing is allowed to be turned 
on and memory refresh to complete. Memory shadowing is not turned back on if 
DUPINT, DUP-CHL or other MAJOR alarms pertinent to memory shadowing are 
not retired. See STBY-SPE for more details as to how the turning on/off of 
shadowing is controlled.
The test duplication-interface and test duplication-interface long commands 
run DUPINT and DUP-CHL tests. This is the only command that can run short 
and long test sequences for these maintenance objects.
Replacement procedures are provided for the standby Duplication Interface 
circuit pack, the active Duplication Interface circuit pack, and the 
interconnecting cable. These procedures are designed to prevent disruption of 
customer service except when the active Duplication Interface circuit pack must 
be replaced because of a failure that prevents memory shadowing. Each 
procedure also describes testing after replacement to verify duplication 
operation when SPE carrier A is active and when SPE carrier B is active. Test 
failures in a procedure can direct you to another procedure for the replacement 
and testing of a related component.
Administration
No add or remove commands are associated with the Duplication Interface 
circuit pack.
In-line Errors
The Local FIFO Full Failure and DUPINT Driver Failure error types can raise 
alarms when in-line errors are received. There are no tests that can retire these 
reported alarms. The command line option of test duplication-interface long 
clear
 with the long test sequence and the clear option is needed to clear alarms 
for these in-line errors. The in-line error types are cleared by this command only if 
no tests fail.
MAJOR vs. MINOR Alarms
DUPINT may have MAJOR or MINOR alarms. Whenever a MAJOR alarm is 
raised, memory shadowing to the standby is turned off. A MINOR alarm does not 
turn off shadowing. Neither type of alarm causes an SPE interchange.
Maintenance Object Interactions
The command test duplication-interface runs both DUPINT and DUP-CHL 
non-destructive tests. The command test duplication-interface long runs both 
DUPINT and DUP-CHL destructive and non-destructive tests. The second 
command can only be run if the standby SPE is busied out. This busy out of the 
standby SPE turns off memory shadowing, and lowers the health of the standby 
to partially-functional; thereby preventing a possible interchange between the