DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-731
DUPINT (Duplication Interface Circuit Pack) 
9
DUPINT (Duplication Interface Circuit 
Pack)
The Duplication Interface (DUPINT) maintenance object tests the active UN330B 
Duplication Interface circuit pack. Tests that fail are recorded in the error and 
alarm log as errors/alarms against the active Duplication Interface circuit pack. 
No errors/alarms are recorded against the standby Duplication Interface circuit 
pack by this maintenance object.
Three Maintenance Objects are utilized in the maintenance of the Duplication 
Interface circuit pack and their cabling. These are DUPINT, DUP-CHL, and 
SPE-SELE. The first of these, DUPINT, is composed of tests that check the 
operation of the active Duplication Interface circuit pack. The second 
maintenance object, DUP-CHL, test overall functionality of the circuit pack. This 
requires both circuit pack, their cabling, and communication with the standby 
software. The third and final MO is SPE-SELE. SPE-SELE monitors the position of 
the select switches located on the front of the Duplication Interface circuit pack.
Testing is directional from the active Duplication Interface circuit pack to the 
standby Duplication Interface circuit pack. If an interchange has occurred with 
alarms raised against DUPINT or DUP-CHL, testing cannot resolve or clear these 
alarms because they are against the wrong circuit pack in the active to standby 
directional configuration. An interchange is needed to allow testing to resolve or 
clear these directional alarms.
Duplication Interface Maintenance Operation
There are six tests that comprise DUPINT. The not-destructive Active DUPINT 
HFAIL test is run as scheduled, periodic and demand short. The Active DUPINT 
Reset test is the destructive version of the HFAIL test and is only run at 
initialization time and on demand long. They are not run as part of periodic or 
scheduled maintenance. Test failures or in-line errors for this maintenance object 
are logged against the active Duplication Interface circuit pack.
The five destructive tests run by DUPINT are only run during initialization (reset 
system 2 or worse) and on demand with the command line of test 
duplication-interface long
. The clear option is needed to clear alarms for error 
types that don’t have an associated test when all of the tests pass or abort. Since 
these tests require the turning on and off of memory shadowing, you must enter 
the command busyout spe before the long sequence may be run. The busying 
out of the SPE turns off memory shadowing but handshaking continues between 
MO Name (in 
Alarm Log)
Alarm 
Level
Initial Command to Run
Full Name of MO
DUPINT
MAJOR
test duplication-interface l c
Duplication Interface circuit pack
DUPINT
MINOR
test duplication-interface l c
Duplication Interface circuit pack