Maintenance Object Repair Procedures 
9-730
DUP-CHL (Duplication Interface) 
9
12. If the SPE Standby State-of-Health is functional as observed with the 
status spe command, use the reset system interchange command. With 
the other SPE now active, execute the busyout spe-standby command 
and use the test duplication-interface long clear command to test the 
Duplication Channel in the other direction, resolving any outstanding 
alarms against DUPINT and DUP-CHL.
If these tests pass, continue with step 13.
13. Execute the release spe-standby command and wait for memory 
shadowing and standby refreshed to complete as verified with the status 
spe
 command.
If the standby is not refreshed within 10 minutes, continue with step 
14.
If the standby is refreshed within 10 minutes, this replacement 
procedure is successfully finished.
14. Use the status spe command. If the status shows MAJOR alarms, use the 
display alarms command with the spe category selection. Resolve 
alarms for maintenance objects other than DUPINT and DUP-CHL.
If the standby is not refreshed within 10 minutes, or the DUPINT and 
DUP-CHL alarms are not resolved, escalate the problem.
If the standby is refreshed within 10 minutes, and the DUPINT and 
DUP-CHL alarms are resolved, this replacement procedure is 
successfully finished.