Maintenance Object Repair Procedures
9-730
DUP-CHL (Duplication Interface)
9
12. If the SPE Standby State-of-Health is functional as observed with the
status spe command, use the reset system interchange command. With
the other SPE now active, execute the busyout spe-standby command
and use the test duplication-interface long clear command to test the
Duplication Channel in the other direction, resolving any outstanding
alarms against DUPINT and DUP-CHL.
the other SPE now active, execute the busyout spe-standby command
and use the test duplication-interface long clear command to test the
Duplication Channel in the other direction, resolving any outstanding
alarms against DUPINT and DUP-CHL.
■
If these tests pass, continue with step 13.
13. Execute the release spe-standby command and wait for memory
shadowing and standby refreshed to complete as verified with the status
spe command.
spe command.
■
If the standby is not refreshed within 10 minutes, continue with step
14.
14.
■
If the standby is refreshed within 10 minutes, this replacement
procedure is successfully finished.
procedure is successfully finished.
14. Use the status spe command. If the status shows MAJOR alarms, use the
display alarms command with the spe category selection. Resolve
alarms for maintenance objects other than DUPINT and DUP-CHL.
alarms for maintenance objects other than DUPINT and DUP-CHL.
■
If the standby is not refreshed within 10 minutes, or the DUPINT and
DUP-CHL alarms are not resolved, escalate the problem.
DUP-CHL alarms are not resolved, escalate the problem.
■
If the standby is refreshed within 10 minutes, and the DUPINT and
DUP-CHL alarms are resolved, this replacement procedure is
successfully finished.
DUP-CHL alarms are resolved, this replacement procedure is
successfully finished.