Generac Power Systems 20 kW LP Manual Do Utilizador

Página de 192
Page 156
Part 6
DISASSEMBLY
sEctioN 6.1
maJor DisassEmBlY
14. Remove  Blower  Housing:  Using  a  4mm  allen  wrench 
remove one button head cap screw from top of blower 
housing. Using a 10mm socket remove one 10mm bolt 
from the top of the blower housing. See Figure 19. Using 
a 10mm socket remove four 10mm bolts from the right-
side  of  the  blower  housing,  (see  Figure  20)  and  four 
10mm bolts from the left-side of the blower housing. See 
Figure 21. Remove blower housing.
Figure 19.
Figure 20.
Figure 21.
major diSaSSemBly
SAFETY:
1.  Set the AUTO-OFF-MANUAL switch to OFF. 
2.  Remove the 7.5 amp main fuse. See Figure 22.
3.  Remove the N1 and N2 fuse from the transfer switch.
Figure 22. Remove 7.5 Amp Fuse
4.  Turn off fuel supply to the generator and remove the flex-
line from the fuel regulator.
5.  Remove utility power from the generator. 
6.  Remove front door.
7.  Remove battery from the generator.