6.  Remove  Left-side  enclosure:  Using  a  10mm  ratchet 
wrench remove the horizontal 10mm bolt that connects 
the side panel to the back panel. Using a 10mm socket, 
remove three bolts from the base of the enclosure. See 
Figure  28.  Using  a  10mm  socket  and  wrench  remove 
the  top  hinge  bolt  and  loosen  the  bottom  bolt.  See 
Figure  29.  Holding  the  roof,  remove  the  bottom  hinge 
bolt, remove the side panel by sliding it forward then re-
install the hinge bolt. 
Figure 28.
Figure 29.
7.  Remove  Fan  Housing  Cover:  Using  a  10mm  socket 
remove four bolts from the fan housing cover. Remove 
the fan housing cover. See Figure 30.
Figure 30.
8.  Remove Rotor Bolt: Using a 9/16” socket, remove rotor 
bolt. Figure 31.
Page 158
Part 6
DISASSEMBLY
sEctioN 6.1
maJor DisassEmBlY