Generac Power Systems 20 kW LP Manual Do Utilizador

Página de 192
STATOR/ROTOR/ENGINE REMOVAL:
1.  Remove Top Exhaust Enclosure Covers: Using a 10mm 
socket, remove the nine bolts from the exhaust top cov-
ers. Remove covers. See Figure 23.
Figure 23.
2.  Remove Side Exhaust Enclosure Cover: Using a 10mm 
socket,  remove  the  five  bolts  from  the  exhaust  side 
cover. Remove side covers. See Figure 24.
Figure 24.
3.  Remove  Exhaust  Flex  Cover:  Using  a  10mm  socket, 
remove the two bolts from the exhaust flex pipe cover. 
Remove the cover. See Figure 25.
Figure 25.
4.  Remove Exhaust Flex Pipe: Using a ½” socket remove 
the  front  and  rear  muffler  clamp.  Slide  exhaust  flex 
toward  engine  completely  exposing  the  muffler  flange. 
See Figure 26.
Figure 26.
5.  Remove Muffler and Tail Pipe: Using a ½” socket remove 
the muffler clamp and tail pipe. Using a 10mm socket, 
remove  the  four  bolts  from  the  muffler  mounts  and 
remove muffler. See Figure 27.
Page 157
DISASSEMBLY
sEctioN 6.1
maJor DisassEmBlY
Part 6