Lucent Technologies R5SI Manual Do Utilizador

Página de 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-980
M/T-PKT (Maintenance/Test Packet Bus Port) 
10
Enter the 
reset board PCSS
 command.
Enter the 
release board PCSS
 command.
2. Wait 15 minutes.
3. If the error recurs, replace the Maintenance/Test circuit pack.
When this alarm is active, the yellow LED is in one of three states:
If there is no activity on the Maintenance/Test circuit pack, the 
yellow LED is off. It is OK to replace the Maintenance/Test circuit 
pack.
If there is an indication of an uncorrectable fault on the Packet Bus, 
the yellow LED will be blinking at a rate of 1 Hz. It is OK to replace 
the Maintenance/Test circuit pack. Ignore the Packet Bus error 
indication, since the Maintenance/Test circuit pack has been 
determined to be defective.
If there is other activity on the Maintenance/Test circuit pack (that 
is, ISDN Test Call), or if there is an indication of a correctable fault 
on the Packet Bus, the yellow LED will be on steady. If there is an 
ISDN Test Call in progress, it must be halted via the 
clear 
isdn-testcall grp/member
 command prior to replacing the circuit 
pack. Ignore the Packet Bus error indication, since the 
Maintenance/Test circuit pack has been determined to be 
defective.
d. This error indicates a failure of the Packet Bus Port Health Inquiry Test. 
Either the Packet Bus Port has reported a self-test failure, or the SPE is 
able to communicate with the Maintenance/Test Circuit Pack but not with 
the Maintenance/Test Circuit Pack Packet Bus Port. Refer to the 
description of the Packet Bus Port Health Inquiry Test, and follow the 
instructions indicated for the failure code that matches the Aux Data field.
System Technician-Demanded Tests: 
Descriptions and Error Codes
Always investigate tests in the order presented in the following tables when 
inspecting errors in the system. By clearing error codes associated with the 
Packet Bus Port Health Inquiry Test,
 for example, you may also clear errors 
generated from other tests in the testing sequence.