DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-981
M/T-PKT (Maintenance/Test Packet Bus Port) 
10
Clear Error Counters (#270)
This test is not an actual test in the strict sense of the word. Many circuit packs 
have counters in the Angel firmware. These counters are used so that CCMS 
(Control Channel Message Set) messages are not continuously sent uplink. 
Using this method, the message are sent once, when the counter reaches some 
preset threshold, and then not sent again until the counter is cleared.
The ports on the Maintenance/Test circuit pack continually run self-tests, 
whenever the port is idle. The Angel uses a counter so that the Background 
Maintenance Failure message is only sent uplink once (this keeps a failed 
port/circuit pack from flooding the SPE with a string of messages). This test is 
used to clear the counter, so that if the port continues to fail during or after 
SPE-demanded testing, the Angel sends a message to indicate that fact.
This test is only used to send a message to the Angel on the Maintenance/Test 
circuit pack. Therefore, this test should never abort or fail.
1.
D = Destructive; ND = Nondestructive
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
D/ND
1
Packet Bus Port Health Inquiry Test 
(#567)
X
X
ND
Clear Error Counters (#270)
X
ND
Table 10-283.
TEST #270 Clear Error Counters 
Error 
Code
Test 
Result
Description/ Recommendation
Any
ABORT
This test should never abort.
Any
FAIL
This test should never fail.
1. Retry the command at one-minute intervals a 
maximum of five times.
2. If the test continues to fail, escalate the problem.
PASS
The message to clear the Maintenance/Test circuit 
pack’s counter for Background Maintenance Failures 
has been sent.
Continued on next page