Lucent Technologies R5SI Manual Do Utilizador

Página de 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-322
reset maintenance 
8
Error Messages
If the cabinet entered is non numeric or not within a valid range, the following 
message will be displayed:
Cabinet number out of range; Enter 2 - 3
If the length of the user entered parameter exceeds three (3), or is in any other 
way invalid, the following message will be displayed:
Entry invalid
If the command entered is in conflict with another currently executing command, 
then a message displays showing the login ID of the conflicting user and the 
conflicting command. The message is as follows:
’login id’:’command’ has a command conflict
Output
For the following output example, assume that the command that was entered is 
"reset maintenance 02a."
Feature Interactions
Running the command from the EPNSAT, will cause the SAT to be dropped 
before the reset results can be displayed. In this case, the user should examine 
the error and alarm logs for "MAINT" entries to determine if the reset failed.
Port
The port address (cabinet-carrier-slot) of the MO being reset.
Maintenance Name
"MAINT" for the EPN maintenance circuit pack.
Alt. Name
Always blank for this command.
Result
The result of the reset -"PASS," "ABORT," "FAIL."
Test No.
The test number for this command will always be 306.
Error Code
A system-generated number that tells why the reset failed or 
aborted. A detailed list of the codes can be in the "Reset 
Commands" section of this chapter.
 
 reset maintenance 02A
                              TEST RESULTS
 Port   Maintenance Name  Alt. Name  Test No.  Result  Error Code
 02A           MAINT                   306      PASS
 Command successfully completed