Lucent Technologies R5SI Manual Do Utilizador

Página de 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-585
test hardware-group 
8
A hardware-group command executing in the foreground may be aborted by 
either pressing the ’cancel’ key on the SAT or by entering the "cancel 
hardware-group" command on a different SAT.
However, if the system technician wishes to cancel a "test hardware-group" 
command running in the background the "cancel hardware-group" command 
needs to be entered on any SAT.
A canceled "test hardware-group" command can be resumed at the point it left 
off by entering the "resume hardware-group" command on the SAT. Restarts are 
not allowed for "test hardware-group" commands entered with either the 
"all-ports" option or the "spe-interchange" option.
Defaults
The default for the command is short with a repeat of 1.
Parameters
carrier location
A ’carrier location’ represents the carrier to be tested and is entered 
as UUC format where ’UU’ is a valid cabinet number (1-3) and the ’C’ 
represents any value between A-E. The type of carrier may be port, or 
processor. In the case of a port carrier, all universal port and 
tone-clock boards (see reference 4) and its affiliated MOs residing in 
the specified carrier are tested. For a processor carrier, all SPE 
complex and tone-clock boards and its affiliated MOs are tested.
cabinet location
A ’cabinet location’ represents the cabinet to be tested. It can be any 
value between 1-3. All PN and PNC related MOs plus cabinet specific 
MOs, including maintenance boards and environment (ring 
generator, battery, power, emergency transfer, external alarms, fans, 
and temperature) will be tested if they reside in the specified ’cabinet 
location’.
board location
A ’board location’ represents the physical location of the board and is 
entered as ’UUCSS’ format, where ’UU’ is a valid cabinet number 
(1-3), ’C’ is a carrier number between A-E, and ’SS’ is the slot position. 
All MOs on the specified ’board location’ including ports will be 
tested.
print
This will cause the report to be printed if a printer is linked to the SAT.
schedule
When the "schedule" option is specified, the command is validated 
and then a scheduling form is displayed to allow the technician to 
schedule execution of the command. The command is then placed in 
the command queue and is executed at the specified time. The 
information displayed by the command is sent to the system printer 
instead of the screen. Refer to the Report Scheduler and System 
Printer feature specification [5] for more details.