Lucent Technologies R5SI Manual Do Utilizador

Página de 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-586
test hardware-group 
8
Help Messages
If the system technician presses 
HELP
 after entering "test hardware-group" the 
following message will be displayed:
board  cabinet  carrier  spe  system
If the system technician presses 
HELP
 after entering "test hardware-group board" 
the following message will be displayed:
Enter board location: [cabinet (1-3);
carrier (A-E);slot(00-20)]
If the system technician presses 
HELP
 after entering "test hardware-group 
cabinet" the following message will be displayed:
Enter cabinet (1-3)
If the system technician presses 
HELP
 after entering "test hardware-group carrier" 
the following message will be displayed:
Enter carrier location: 
[’cabinet’(1-3)]; carrier (A-E)
If the system technician presses 
HELP
 after entering "test hardware-group system" 
the following message will be displayed:
Entry is not required
If the system technician presses 
HELP
 after entering "test hardware-group spe" 
the following message will be displayed:
Entry is not required
Error Messages
If there is another "test hardware-group" active the following message will be 
displayed:
Command aborted - another hardware-group
test already in progress
If an "add station" command is entered for a non-customer translated port at the 
same time as it is being tested because of the "test hardware-group" command 
with the ’all-ports’ option the request to "add station" will fail and the following 
message will be displayed:
Object in use; please try later
If an invalid physical location is specified with the "test hardware-group board" 
command the following message will be displayed:
Board invalid
If an unassigned board is specified with the "test hardware-group board" 
command the following message will be displayed: