Maintenance Commands and Trouble-Clearing Aids 
Page 8-587
test hardware-group 
8
Board not assigned
If an invalid carrier is specified with the "test hardware-group carrier" command 
the following message will be displayed:
Invalid carrier specified
If an invalid cabinet is specified with the "test hardware-group cabinet" command 
the following message will be displayed:
Invalid cabinet specified
If the command entered is in conflict with another currently executing command, 
then a message will be displayed showing the login id of the conflicting user and 
the conflicting command. The message is as follows:
’login id’:’command’ has a command conflict
FORM INPUT
Once the user has entered the desired action (test hardware-group) and the 
object (board, carrier, etc.), then the user is presented with an options form.
Test sequence
This allows the user to specify whether the short (nondestructive) or 
the long (more comprehensive and still nondestructive) test sequence 
should be exercised.
Test Repetition
This allows the user to enter either ’repeat’ with a corresponding 
repeat value (between 1 and 99) or ’continuously’. The repeat option 
will cause each test to be executed the number of times specified on 
each physical object. The continuously option, on the other hand, will 
cause all tests on all the hardware specified to be executed until the 
CANCEL key is hit or the ’cancel hardware-group’ command is run.
count:
This field allows the technician to enter a repeat value between 1 and 
99. If the ’test sequence’ field is set to continuously, then this field is 
removed from the screen. When the ’test sequence’ field is set to 
repeat, then this field is added to the screen.
Auto-page?
This option provides the ability to continue testing and display of test 
results by providing a new screen every time the SAT screen is filled 
with test results. The screen does not scroll to accommodate new 
results; instead a new screen is provided after the current screen fills 
up.
This option is not allowed if the ’background’ option has been chosen.
If the ’auto-page’ option is not specified, the SAT screen will not be 
refreshed once it is filled with test results and testing will stop until the 
user enters the ’page’ key to continue or ’cancel’ key to halt the testing.