5.5.7.  Remote Register Assignment 
Divide the monitor code (RWw n) into half and select the monitor value 1 (RWr n) from the 
lower 8 bits and the monitor value 2 (RWr n) from the higher 8 bits.   
For example: When output voltage is selected for the monitor value 1 and output torque is 
selected for the monitor value 2. -> The monitor code is 0703H. 
* The hexadecimal value attaches and expresses "H" to the end of a number. 
 
1. Remote register (Master -> inverter) 
RWw 
Address Signal 
Description 
RWw n 
Monitor code   
(1 and 2) 
Set the monitor code to be referenced. By switching on the (RYnC) signal   
after setting, the specified monitored data is set to (RWr n). 
The monitor value 1 (RWr n): RWw n Setting of the lower 8 bits of monitor   
code. 
The monitor value 2 (RWr n+1): RWw n Setting of the upper 8 bits of   
monitor code. 
RWwn+1 Set 
frequency 
Set the set frequency. After setting the register, a frequency is written 
after turning on (RynD). When the writing of the frequency is completed, 
(RXnD) turns on, depending on the input command. 
Unit: 0.01Hz 
RWwn+2 
Command code 1 
Set the command code for actions such as operation mode switching,   
parameter read, write, error reference, error clear, etc. The command will 
be executed by turning (RynF) on after the register setting is completed. 
When the command execution is completed, (RXnF) turns on.   
RWwn+3 
Write data 1 
Set data specified by the above-mentioned command code   
(if necessary). 
If no data needs to be written, the value shall be zero.   
(RynF) is turned on after setting the above-mentioned command code 
and this register.   
RWwn+4 
Monitor code 3 
Set the monitor code to be monitored. By setting "ON” in (RYC) after 
setting, the specified monitored data is stored in RWr n+4. 
RWwn+5 
Monitor code 4 
Set the monitor code to be monitored. By setting "ON” in (RYC) after 
setting, the specified monitored data is stored in RWr n+5.   
RWwn+6 
Monitor code 5 
Set the monitor code to be monitored. By setting "ON” in (RYC) after 
setting, the specified monitored data is stored in RWr n+6.   
RWwn+7 
Monitor code 6 
Set the monitor code to be monitored. By setting "ON” in (RYC) after 
setting, the specified monitored data is stored in RWr n+7.   
RWwn+8 Trip 
history 
No. 
Set how many fault records in past to be read.   
Upper 8 bits: H00 (latest fault) to H07 (eight faults in past) 
Lower 8 bits: H00 
RWwn+9 
to  
RWwn+F 
Reserved 
Reserved