McDATA 3000 Manual Do Utilizador

Página de 428
5
5-24
McDATA UltraNet Edge 3000 User Guide
Delivering the Configured Network
The Network Map will appear and should look like this:
This completes the procedure for FC/IP data path mapping.
If you are configuring a 2x2, repeat the steps in both the “Adding 
an IP Circuit”
 and the “Creating a Data Path” sections.
Proceed to the “Delivering the Configured Network” section in 
this chapter.
Delivering the Configured Network
Now that you have configured a sample network, or if you made 
changes to the configuration parameters, you must deliver the 
configuration information for each node defined on the active 
network map to the actual nodes.
The configuration information can be delivered in two different 
ways, File>Deliver Network or File>Delivery Wizard.
The configurations can be delivered via the Maintenance Port IP or 
the PPP Port IP. If you do not have direct IP connectivity, use the PPP 
option. See “Setting the Delivery Properties” below.
Note:
If you used the “Manual Configuration of the Initial 
IP Settings” procedure in Appendix H, complete the 
“Update UltraNet ConfigManager with the Manual 
Configurations” procedure before delivering the 
configured network.