2  Troubleshooting Procedures  
2.3  Power Supply Troubleshooting
 
Procedure 2 
Error Code Check  
If the power supply microprocessor detects a malfunction, the DC IN icon blinks orange. The 
blink pattern indicates an error as shown below. 
 Start          Off 
for 
seconds 
 Error code (8 bit)   
“1” 
          On 
for 
one 
second 
“0” 
          On 
for 
half 
second 
Interval between data bits     Off 
for 
half 
second 
The error code begins with the least significant digit. 
Example:  Error code = 12h (Error codes are given in hexadecimal format.) 
 