Справочник Пользователя для Toshiba M30-35
![Toshiba](https://files.manualsbrain.com/attachments/acaaaa9cc6b763ccfc72ced2ae95d9c94b8b8632/common/fit/150/50/8adbcbcd45c75dc53932fc9caf6f2740daed52d836b76efbd0162ac2599f/brand_logo.png)
2 Troubleshooting Procedures
2.3 Power Supply Troubleshooting
Procedure 2
Error Code Check
If the power supply microprocessor detects a malfunction, the DC IN icon blinks orange. The
blink pattern indicates an error as shown below.
blink pattern indicates an error as shown below.
Start Off
for
2
seconds
Error code (8 bit)
“1”
On
for
one
second
“0”
On
for
a
half
second
Interval between data bits Off
for
a
half
second
The error code begins with the least significant digit.
Example: Error code = 12h (Error codes are given in hexadecimal format.)
2-8
Satellite M30-35 Maintenance Manual (960-455)