GTO 12 Manual Do Utilizador

Página de 40
18
  GTO 4000XLS Instruction Manual © 01.10.12
DIP Switches
DIP Switch Settings (MODES)
DIP Switch #1:   Soft Start/Stop
 
  ON– Soft start enabled (factory 
preset).
 
  OFF– Soft start disabled.
 
  The Soft Start/Stop feature slowly 
starts the gate as it begins to open 
and slows the gate as it comes 
to the closed position. This saves 
wear and tear on the gate and gate 
operator system.
DIP Switch #2:  Warning Buzzer
 
  ON– Buzzer warning enabled 
(factory preset).
 
  OFF– Buzzer warning disabled.
 
  The Warning Buzzer alerts 
you when the gate operator is 
beginning to either open or close 
the gate. It sounds for the first 2 
seconds in each direction. It also 
sounds a warning when the gate 
obstructs two times in one cycle. 
Switching this to OFF only disables 
the open and close warning not 
the obstruction warning.
DIP Switch #3:   Push/Pull-To-Open
 
  ON: Push-To-Open.
 
  OFF: Pull-To-Open (factory preset).
 
  If your gate opens into the 
property the DIP Switch is set to 
the OFF position (factory setting). 
If your gate opens out from the 
property the DIP Switch must be 
set to the ON position. NOTE: if 
you have a Push-to-Open gate 
application you will need a Push-
To-Open bracket (see Push-To-
Open Instructions on page 21).
DIP Switch #4:  Dual Operation
 
  ON– Second opens simultaneously 
with master.
 
  OFF– Second opens after master 
(factory preset).
 
  Note: Not applicable for single gate 
operator.
DIP Switch Settings
1  2  3  4
ON    DIP
STATUS
LEARN  RMT
LEARN
MAST  LIMIT 
LEARN
2ND    LIMIT 
S3
S4
S2
OFF
SOFT  START  OFF
WARNING       OFF
OPEN                PULL
2ND    OPEN     DLY.
MODE1               OFF
MODE2               OFF
ON
ON
PUSH
SIMULT.
ON
ON
120 MIN
MAX
AUTO CLOSE  TIME 
STALL   FORCE
1  2  3  4
ON    DIP
SOFT  START  OFF
WARNING       OFF
OPEN                PULL
2ND    OPEN     DLY.
MODE1               OFF
MODE2               OFF
ON
ON
PUSH
SIMULT.
ON
ON
120 MIN
ON
OFF
1
ON 
DIP
2
3
4