GTO 12 Manual Do Utilizador

Página de 40
  GTO 4000XLS Instruction Manual © 01.10.12  
19
Connecting Accessories
Input Connections
•  All control inputs are dry-contact, normally open, inputs. DO NOT apply external voltage sources to
these inputs.
•  All inputs are connected with respect to COMMON terminal.
•  The status LED will blink once when its corresponding input is activated.
1 COM:  Circuit common (reference for 
all logic input)
• Two (2) terminals to provide extra
common connection point.
2 CYCLE/CLOSE: 
 (Typically for use 
with push button or hard-wired 
keypad)
•  Each activation at this input will
cycle the operation as follows:
   OPEN–STOP–CLOSE–STOP–OPEN 
3 SAFETY:  (Typically for use with 
photo beam device, loop detector 
or other non-contact sensors)
•  Activation of this input while the
gate is closing will cause the gate 
to stop and return to the opened 
position.
•  Activation of this input while the
gate is opening has no effect (gate 
will continue to open).
•  Activation of this input while
gate is idle will prevent gate from 
closing.
4 EXIT/OPEN:  (Typically for use with 
exit loop or wand)
•  Activation of this input will open
the gate if it’s not already at the open position
•  Activation of this input while at open limit will restart the auto close time (if enabled).
•  Activation of this input while gate at the fully open position will prevent gate from closing.
5  SHADOW LOOP:  (Typically for use with loop detector)
•  This input is only monitored when the gate is at the fully open position. At any other position,
activation of this input has no effect on gate operation.
•  Activation of this input while gate at the fully open position will prevent gate from closing.
6  CLOSE EDGE:  (Typically for use with safety edge device)
•  Activation of this input while the gate is closing will cause the gate to stop and reverse direction for
approximately 2 seconds.
•  Activation of this input while the gate is opening has no effect (gate will continue to open).
•  Activation of this input while gate is idle will prevent gate from closing.
7  OPEN EDGE:  (Typically for use with safety edge device)
•  Activation of this input while the gate is opening will cause the gate to stop and reverse direction for
approximately 2 seconds.
•  Activation of this input while the gate is closing has no effect (gate will continue to close).
•  Activation of this input while gate is idle will prevent gate from opening.
GR
N
CO
MC
OM
CYCLE
CLOSE
SAFETY
SHADOW
LOOP
CLOSE
EDGE
OPEN
EDGE
EXIT
OPEN
BL
K
RECEIVER
RED
RECEIVER
ALM
C
ONTROL INPUT
S
1
2
3
4
7
5
6