Renesas R5S72623 Manual Do Utilizador

Página de 2152
 
 
Section 11   Multi-Function Timer Pulse Unit 2 
 
Page 620 of 2108 
 
R01UH0134EJ0400  Rev. 4.00 
 
 Sep 
24, 
2014 
SH7262 Group, SH7264 Group
(2)  Operation when Error Occurs during Normal Mode Operation, and Operation is 
Restarted in PWM Mode 1 
Figure 11.116 shows an explanatory diagram of the case where an error occurs in normal mode 
and operation is restarted in PWM mode 1 after re-setting. 
1
RESET
2
TMDR
(normal)
3
TOER
(1)
5
PFC
(MTU2)
4
TIOR
(1 init
0 out)
6
TSTR
(1)
7
Match
8
Error 
occurs
9
PFC
(PORT)
10
TSTR
(0)
11
TMDR
(PWM1)
12
TIOR
(1 init
0 out)
13
PFC
(MTU2)
14
TSTR
(1)
MTU2 module output
TIOC*A
TIOC*B
Port output
PEn
PEn
Not initialized (TIOC*B)
n = 0 to 15
High-Z
High-Z
 
Figure 11.116   Error Occurrence in Normal Mode, Recovery in PWM Mode 1 
1 to 10 are the same as in figure 11.115. 
11.  Set PWM mode 1. 
12.  Initialize the pins with TIOR. (In PWM mode 1, the TIOC*B side is not initialized. If 
initialization is required, initialize in normal mode, and then switch to PWM mode 1.) 
13.  Set the multi-function timer pulse unit 2 output with the general I/O port. 
14.  Operation is restarted by TSTR.