Section 11   Multi-Function Timer Pulse Unit 2 
 
Page 622 of 2108 
 
R01UH0134EJ0400  Rev. 4.00 
 
 Sep 
24, 
2014 
SH7262 Group, SH7264 Group
(4)  Operation when Error Occurs during Normal Mode Operation, and Operation is 
Restarted in Phase Counting Mode 
Figure 11.118 shows an explanatory diagram of the case where an error occurs in normal mode 
and operation is restarted in phase counting mode after re-setting. 
1
RESET
2
TMDR
(normal)
3
TOER
(1)
5
PFC
(MTU2)
4
TIOR
(1 init
0 out)
6
TSTR
(1)
7
Match
8
Error 
occurs
9
PFC
(PORT)
10
TSTR
(0)
11
TMDR
(PCM)
12
TIOR
(1 init
0 out)
13
PFC
(MTU2)
14
TSTR
(1)
MTU2 module output
TIOC*A
TIOC*B
Port output
PEn
PEn
n = 0 to 15
High-Z
High-Z
 
Figure 11.118   Error Occurrence in Normal Mode, Recovery in Phase Counting Mode 
1 to 10 are the same as in figure 11.115. 
11.  Set phase counting mode. 
12.  Initialize the pins with TIOR. 
13.  Set the multi-function timer pulse unit 2 output with the general I/O port. 
14.  Operation is restarted by TSTR. 
 
Note:  Phase counting mode can only be set for channels 1 and 2, and therefore TOER setting is 
not necessary.