Renesas R5S72623 Manual Do Utilizador

Página de 2152
 
Section 11   Multi-Function Timer Pulse Unit 2 
 
R01UH0134EJ0400  Rev. 4.00  
 
Page 621 of 2108 
Sep 24, 2014 
 
 
 
SH7262 Group, SH7264 Group 
(3)  Operation when Error Occurs during Normal Mode Operation, and Operation is 
Restarted in PWM Mode 2 
Figure 11.117 shows an explanatory diagram of the case where an error occurs in normal mode 
and operation is restarted in PWM mode 2 after re-setting. 
1
RESET
2
TMDR
(normal)
3
TOER
(1)
5
PFC
(MTU2)
4
TIOR
(1 init
0 out)
6
TSTR
(1)
7
Match
8
Error 
occurs
9
PFC
(PORT)
10
TSTR
(0)
11
TMDR
(PWM2)
12
TIOR
(1 init
0 out)
13
PFC
(MTU2)
14
TSTR
(1)
MTU2 module output
TIOC*A
TIOC*B
Port output
PEn
PEn
Not initialized (cycle register)
n = 0 to 15
High-Z
High-Z
 
Figure 11.117   Error Occurrence in Normal Mode, Recovery in PWM Mode 2 
1 to 10 are the same as in figure 11.115. 
11.  Set PWM mode 2. 
12.  Initialize the pins with TIOR. (In PWM mode 2, the cycle register pins are not initialized. If 
initialization is required, initialize in normal mode, and then switch to PWM mode 2.) 
13.  Set the multi-function timer pulse unit 2 output with the general I/O port. 
14.  Operation is restarted by TSTR. 
 
Note:  PWM mode 2 can only be set for channels 0 to 2, and therefore TOER setting is not 
necessary.