VR8104, VR8204 AND VR8304 INTERMITTENT PILOT COMBINATION GAS CONTROLS
9
69-1225—4
Check and Adjust Gas Input 
and Burner Ignition
IMPORTANT
1. Do not exceed input rating stamped on 
appliance nameplate, or manufacturer’s 
recommended burner orifice pressure for size 
orifice(s) used. Make certain primary air supply 
to main burner is properly adjusted for complete 
combustion. Follow appliance manufacturer 
instructions.
2. IF CHECKING GAS INPUT BY CLOCKING 
GAS METER: Make certain there is no gas flow 
through the meter other than to the appliance 
being checked. Other appliances must remain 
off with the pilots extinguished (or deduct their 
consumption from the meter reading). Convert 
flow rate to Btuh as described in form 70-2602, 
Gas Controls Handbook, and compare to Btuh 
input rating on appliance nameplate.
3. IF CHECKING GAS INPUT WITH 
MANOMETER: Make sure the gas control knob 
is in the OFF position before removing outlet 
pressure tap plug to connect manometer 
(pressure gauge). Also move the gas control 
knob to the OFF position when removing the 
gauge and replacing the plug. Before removing 
inlet pressure tap plug, shut off gas supply at 
the manual valve in the gas piping to the 
appliance or, for LP, at the tank. Also shut off 
gas supply before disconnecting manometer 
and replacing plug. Repeat Gas Leak Test at 
plug with main burner operating.
NOTE:
Check the inlet pressure before adjusting the 
pressure regulator.
Standard and Slow-Opening 
(H, K and M) Models 
1.
Carefully check the main burner lightoff. Make sure 
that the main burner lights smoothly and that all 
ports remain lit.
2.
Check the full rate manifold pressure listed on the 
appliance nameplate. Gas control full rate outlet 
pressure should match this rating.
3.
With main burner operating, check the control flow 
rate using the meter clocking method or check 
pressure using a manometer connected to the 
outlet pressure tap on the control. See Fig. 6.
4.
If necessary, adjust the pressure regulator to 
match the appliance rating. See Tables 8A and 8B 
for factory-set nominal outlet pressure and 
adjustment range.
a. Remove the pressure regulator adjustment cap 
screw.
b. Using a screwdriver, turn the inner adjustment 
screw (Fig. 6) clockwise
 to increase or 
counterclockwise
 to decrease the gas 
pressure to the burner.
c. Always replace the cap screw and tighten 
firmly to prevent gas leakage.
5.
 If the desired outlet pressure or flow rate cannot 
be achieved by adjusting the gas control, check the 
gas control inlet pressure using a manometer at 
the inlet pressure tap of the gas control. If the inlet 
pressure is in the nominal range (see Tables 8A 
and 8B), replace the gas control. Otherwise, take 
the necessary steps to provide proper gas 
pressure to the control.
NOTE:
If the burner firing rate is above 150,000 Btuh 
on VR8304 models (see Table 1 for VR8304 
capacities), it may not be possible to deliver the 
desired outlet pressure. This is an application 
issue, not a control failure. Take whatever steps 
are required to correct the situation.
Step-Opening (P) Models 
Step-opening models require that you check and adjust 
the full-rate pressure first and then check the step 
pressure. The step pressure is not field adjustable.
1.
Carefully check the main burner lightoff. Make sure 
that the main burner lights smoothly and that all 
ports remain lit.
2.
Check the full rate manifold pressure listed on the 
appliance nameplate. Gas control full rate outlet 
pressure should match this rating.
3.
With main burner operating, check the gas control 
flow rate using the meter clocking method or check 
pressure using a manometer connected to the 
outlet pressure tap on the gas control. See Fig. 6.
4.
If necessary, adjust the pressure regulator to 
match the appliance rating. See Tables 8A and 8B 
for factory-set nominal outlet pressure and 
adjustment range.
a. Remove the pressure regulator adjustment cap 
screw.
Using a screwdriver, turn the inner adjustment screw 
(Fig. 6) clockwise
 to increase or 
counterclockwise
 to decrease the gas pressure 
to the burner.
b. Always replace the cap screw and tighten 
firmly to prevent gas leakage.
5.
If the desired outlet pressure or flow rate cannot be 
achieved by adjusting the gas control, check the 
gas control inlet pressure using a manometer at 
the inlet pressure tap of the control. If the inlet 
pressure is in the nominal range (see Tables 8A 
and 8B), replace the control. Otherwise, take the 
necessary steps to provide proper gas pressure to 
the control.
6.
Carefully check the burner lightoff at step pressure. 
Make sure the burner lights smoothly and without 
flashback to the orifice. Make sure all ports remain 
lit. Cycle the burner several times, allowing at least 
60 seconds between cycles for the regulator to 
resume the step function. Repeat after allowing the 
burner to cool. Readjust the full rate outlet 
pressure, if necessary, to improve lightoff 
characteristics. 
Two-Stage (Q) Models 
Two-stage models require that you check and adjust both 
high and low pressure regulator settings. Two-stage 
appliance operating sequences vary. Consult the 
appliance manufacturer instructions for the specific 
operating sequence and regulator adjustment procedure 
for the appliance in which the control is installed. 
1.
Set appliance to operate on high. 
2.
Carefully check the main burner lightoff. Make sure 
that the main burner lights smoothly and that all 
ports remain lit.
3.
Check the full rate (high) manifold pressure listed 
on the appliance nameplate for high pressure. The 
gas control full rate outlet pressure should match 
this rating.