17.6.2  SNMP Traps 
The P-660HWP-Dx will send traps to the SNMP manager when any one of the following 
events occurs:
17.6.3  Configuring SNMP
To change your P-660HWP-Dx’s SNMP settings, click Advanced > Remote MGMT > 
SNMP. The screen appears as shown.
Figure 141   Remote Management: SNMP
Table 101   SNMP Traps
TRAP #
TRAP NAME
DESCRIPTION
0
coldStart (defined in RFC-1215)
A trap is sent after booting (power on).
1
warmStart (defined in RFC-1215)
A trap is sent after booting (software reboot).
6
whyReboot (defined in ZYXEL-
MIB)
A trap is sent with the reason of restart before 
rebooting when the system is going to restart (warm 
start).
6a
For intentional reboot:
A trap is sent with the message "System reboot by 
user!" if reboot is done intentionally, (for example, 
download new files, CI command "sys reboot", etc.).
6b
For fatal error: 
A trap is sent with the message of the fatal code if the 
system reboots because of fatal errors.