Citel 3000 Guia Do Utilizador

Página de 120
EXTender 3000 System Administrator’s Guide (Definity)
Troubleshooting
Page 97
LED Sequences
The LED sequences on the Office and Remote Modules are indicators of the status of the extenders during 
power up. Please refer to the tables below if you experience problems when powering up or during normal 
operation.
LED Power-up Verification Errors
The LED blink sequences in Table 18 indicate other blink sequences that may be observed if there are prob-
lems during the power-up sequence.
Table 17: LED Power-up Hardware Test Sequences
LED Sequence
Description
No LED blinks.
Error with hardware or AC adapter.
First blink: Red or Green
LED is not functioning properly as units should blink Yellow.
Yellow
Checksum test failed.
Yellow & 1 Red
DRAM, Data test failed
Yellow & 2 Red
DRAM Address test failed
Yellow & 3 Red
DUART, test failed.
Yellow & 7 Reds & 1 Green
Passed all hardware tests
Table 18: LED Power-up Verification Error Sequences
LED Sequence
Description
Solid yellow with green blinks indicates 
the decompress state. If there was a prob-
lem decompressing you will see a repeat-
ing series of yellow and red blinks with 
no pauses.
Decompress failed. The number of red blinks between each 
yellow blink indicates the decompression error. Power cycle 
unit and if problem continues then contact Customer Support.
1 Red - not a valid compressed image.
2 Red - invalid compression method
3 red – invalid compression flags.
4 red – decompression error.
5 red – CRC mismatch.
6 red – length mismatch.
After the Hardware Tests there will be a 
period where the LED flickers red. The 
length of time depends on whether or not 
a software upgrade or flash error has 
occurred.
10 to 15 seconds red flicker - FLASH code is being veri-
fied and if valid will be executed.
25 to 30 seconds red flicker - FLASH code is invalid 
EPROM code is copied to FLASH.
After the flash is verified (red flicker) 
there will be a period of FLASH code 
decompression (solid yellow with green 
blinks). But if the flash verification failed 
then we will continue running the 
EPROM code. This is indicated by 3 red 
blinks.
Solid yellow with green blinks - flash verification 
passed, decompressing flash code.
3 red blinks - Running EPROM code, FLASH write 
failed. Contact Customer Support.