EXTender 3000 System Administrator’s Guide (Definity)
Troubleshooting
The Extender will proceed through a series of blink sequences as it performs the power-on self-test and 
loads the runtime software into memory. Table 5 describes the meaning of these blink sequences as the 
power-up process is run.
During normal operation, after the power-up process is completed, the LED will repeatedly flash a set of 
four blinks followed by a brief pause. Table 18 below describes the meaning of these blinks.
LED blinking green and red continu-
ously
Invalid/incompatible software was loaded on the unit. 
Cycle the power to revert to EPROM code. If problem 
continues contact customer support.
Table 19: Normal LED Power-Up Blink Sequence
LED Indication
Startup State
Off
Power Off.
Solid yellow. If this blink is any other color than yellow 
then the LED is defective.
Power first applied to the unit.
7 quick red blinks.
Hardware check. Refer to Table 17: LED 
Power-up Hardware Test Sequences above.
Red flickering. (10 to 40 seconds) the LED will flicker at 
different rates for each of erasing, programming, or verify-
ing the flash code. Normally only the very fast flicker will 
be observed while the flash code is verified. Erasing and 
programming LED flicker rates will only be observed 
when upgrading the Extender firmware.
Erasing/Programming verifying flash 
codes.
Solid green. 
Flash code verification complete.
Solid yellow with green blinks, ending with solid green. 
This whole sequence last about 20 seconds.
Decompress the flash runtime image.
3 green blinks. 
Running flash runtime image.
Two sets of yellow, yellow, red, red.
System startup.
Three sets of 8 yellow blinks.
Power-up Access to Terminal Configura-
tion Menu at 9600, N, 8, 1 on COM1 by 
typing menu.
Repeating set of four blinks: Refer to Table 20: below for a 
description of there meaning.
Normal Operation.
Table 18: LED Power-up Verification Error Sequences
LED Sequence
Description