Cisco Cisco UCS B260 M4 Blade Server Ficha De Dados

Página de 64
Cisco UCS B460 M4 Blade Server (with Intel® Xeon E7 v2 CPU)
54
SUPPLEMENTAL MATERIAL
, no VIC 1340/1240 is installed. Adapter 2 slot is also not occupied. The VIC 1380/1280 installed 
in adapter slot 3 channels four ports to each of the Fabric Extenders. The result is 40 Gb of bandwidth to 
each Fabric Extender.
Figure 14
  No VIC 1340/1240 installed, no adapter installed in slot 2, and VIC 1380/1280 in slot 3
In 
, two ports from the VIC 1340/1240 are channeled to Fabric Extender A and two are channeled 
to Fabric Extender B. The Port Expander Card installed in adapter slot 2 acts as a pass-through device, 
channeling two ports to each of the Fabric Extenders. A Cisco UCS storage accelerator is installed in slot 3, 
but provides no network connectivity. The result is 40 Gb of bandwidth to each Fabric Extender.
Figure 15
  VIC 1340/1240 and Port Expander in Adapter Slot 2 with UCS storage accelerator in slot 3