Cisco Cisco Aironet 340 Ethernet Bridges Guia Do Utilizador

Página de 218
11 - 12    Aironet 340 Series Bridge
This allows you to specify a bit mask and corresponding hexa-
decimal value to be applied to the packet. These two values must 
match the packet contents before the protocol is identified.
You must first specify a mask start position in the packet and 
match the mask value. The mask start position value should be a 
0-based byte offset from the start of the data portion of the 
frame (after the MAC layer header). If you set the position to 
“none”, no mask is tested.
c.
Type a mask start position value (or “none”, if applicable) and 
press  ENTER.
Enter a hex value of 1 to 30 characters :
d.
Type the value to be matched as a string of up to 30 hexadecimal 
digits and press ENTER. If the numbered digits is odd, the 
mask value will be adjusted to ignore the low 4 bits of the corre-
sponding byte.
Enter a hex don’t care mask of 1 to 6 characters :
This allows you to enter a string of hexadecimal digits to indi-
cate which bits of the packet data are meaningful. 
A bit set in this value causes the corresponding bit in the packet 
to be ignored. Therefore, a 0 mask means that the packet con-
tents must exactly match the previous value entered. If the mask 
entered is shorter than the value entered it is automatically 
extended to the correct length with zeros.
e.
Type the applicable hexadecimal digits and press ENTER.
For example, to enter a mask that matches the value 4128H in 
the 16th byte data portion of the packet and have the high bit of 
each byte ignored, complete as follows:
Enter one of [a mask start position, none] : 15
Enter a hex value of 1 to 30 characters : 4128   
Enter a hex don’t care mask of 1 to 4 characters : 
8080