Crestron cnxenet plus Manual Do Utilizador

Página de 32
CNX Enhanced Ethernet Expansion Card 
Crestron CNXENET+
 
CNMSX Installation (1 of 3) 
3
1
2
REAR PANEL
(REFERENCE ONLY)
 
2. Remove 
six screws   from each side of the control system. 
3.  Lift and remove control system top cover  .  
4.  As shown below, remove six screws   that secure I/O printed circuit 
board   to the control system. 
CNMSX Installation (2 of 3) 
8
7
4
5
6
REAR PANEL
(REFERENCE ONLY)
 
5.  Slide the I/O printed circuit board   toward the front panel of the 
control system so that the rear connectors are clear of the rear panel 
slots and reposition the I/O printed circuit board   to gain access to the 
LAN/DPA cover plate  . 
6.  Using a #1 Phillips tip screwdriver, remove two screws   and two 
lock washers   that secure the LAN/DPA cover plate   to the control 
system rear panel. 
7.  From inside the control system, remove the LAN/DPA cover plate  .  
8.  For older model control systems, carefully push the computer interface 
ribbon cable aside to make room for the CNXENET+. For newer 
systems, make sure that cable does not interfere with CNXENET+ 
placement. 
4  
  CNX Enhanced Ethernet Expansion Card: CNXENET+ 
Operations & Installation Guide – DOC. 8153A