A
Building Safety. Building Security.
•   For application in small systems
•   Up to 6 detector zones in conventional 
technology
•   Differentiation between the activation 
of automatic detectors and manual call 
points on the same detector line
•   Evacuation function (NEN 2575)
•   Tested to EN 54-2, -4 by VdS
Fire is a permanent threat to life and property. There-
fore, immediate response to a fi re is imperative. The 
main  objective  of  the  Fire  Detection  Control  Panel 
 Series BC06 is to alarm and to react in time and, con-
sequently, save lives and protect property. For decades 
LST have focused their aims to undertaking unrivaled 
efforts in order to realise new innovations in the security 
area. Research, development and production are loca-
ted within LST premises, thus guaranteeing fl exible and 
reliable individual solutions.
Using a powerful processor system and a large num-
ber of integrated functions, the Fire Detection Control 
Panels  Series  BC06  ensure  topmost  effi ciency  and 
speed –  prerequisites  for  saving  lives  and  minimising 
damage to property.
Description
Already in the basic version the Fire Detection Control 
Panels BC06-1 and BC06-2 are equipped with four de-
tector lines and, owing to its sophisticated factory set-
tings, are immediately ready for operation. This allows 
for quick and effi cient application of the product.
The conventional technology allows for the connection 
of automatic and non-automatic fi re detectors as well as 
a wide range of special detectors with contact output. 
Alarms from manual call points and from automatic de-
tectors that are connected together to one detector line 
can be differentiated and thus evaluated differently by 
the fi re detection control panel, by means of an optional 
coding module.
Thanks  to  the  two  auxiliary  inputs  whose  parameters 
can  be  freely  set  as  well  as  the  eight  open-collector 
outputs with predefi ned function, manifold tasks in the 
fi eld of fi re alarm technology can be realised.
The  optional  evacuation  function  serves  for  the  actu-
ation of alarming devices independent from activated 
alarms.  Depending  on  the  parameterisation,  different 
country-specifi c  regulations  (e.g.,  NEN 2575)  can  be 
fulfi lled.
The Fire Detection Control Panels BC06-1 and BC06-2 
provide a slot for the installation of the optional Zone 
Extension  Board  ZEB2-1.  With  this  expansion  module 
the control panel can be upgraded from four to six de-
tector zones.
A  printer  for  the  event  log  can  be  connected  via  the 
optional Serial Interface Module SIM06-1.
The Fire Detection Control Panel BC06-2 differs from 
the BC06-1 by the additionally integrated 4-digit electro-
nic alarm counter.