Runco PlasmaWall Owner’s Operating Manual
49 
PRE
L
IMINAR
Y
6.1 
RS-232 Connection 
and Port Configuration
To interface the PlasmaWall with a home theater automation/control system or a PC 
running terminal emulation software, connect it to the RS-232 output of the DHD 
Controller as shown in Figure 3-4. Connect your control system or PC to the RS-232 input 
of the DHD Controller as shown in Figure 3-9. 
Configure the RS-232 controller or PC serial port as follows: no parity, 8 data bits, 1 stop 
bit and no flow control. Set the baud rate to 19200, to match that of the DHD Controller 
RS-232 port. 
6.2 
Serial Command 
Syntax
Serial commands to the DHD Controller take the following form:
• Commands are not case-sensitive. 
• For a single command that takes no parameters, type the command followed by a 
carriage return; for example, to set the aspect ratio to Letterbox, type 
LETTERBOX <Enter>
• For a single command that takes a parameter, type the command, a space or a 
comma and the desired value followed by a carriage return; for example, to set the 
brightness to -10, type 
BRIGHTNESS -10 <Enter>
 or 
BRIGHTNESS,-10 <Enter>
• You can also send a string of multiple commands on a single line, separated by 
commas. For example, 
COMPOSITE,BRIGHTNESS 100,ANAMORPHIC <Enter>
 
switches to the Composite video input, sets the brightness to 100 and sets the aspect 
ratio to Anamorphic. Command strings can be up to 255 characters long. 
 
Table 6-1 lists the RS-232 command set. The “Parameter (min/max)” column shows the 
valid parameter ranges, or “NA” for commands that take no parameters. 
When you enter a valid command, the DHD Controller executes it and acknowledges it 
with a plus sign on the command line (+ >). When you enter an invalid command – one 
that is misspelled or followed by values outside the valid range for that command – the 
DHD Controller ignores it and returns a minus sign (- >).
6. Serial Communications
Avoid combining the 
ON
 or 
POWER 1
 commands with other commands 
on a single line. After sending 
ON
 or 
POWER 1, 
allow at least 15 
seconds for the DHD Controller to power up. Once it does, it will accept 
and properly execute multiple serial commands. 
Table 6-1. Serial Commands 
Command
Parameter 
(min/max)
Value 
Stored?
Description
Power On/Off Commands
OFF
NA
NA
Turns system off
ON
NA
NA
Turns system on
POWER
0/1
NA
Turns system on or off (toggles on/off state)
POWER?
NA
NA
Returns power status
Note