Puls UB10.241 UPS Guia De Especificação

Página de 23
 
 
 
UB10.241 
 
  USeries 
24V, 10A, DC-UPS 
 
 
 
14.  F
RONT 
S
IDE 
U
SER 
E
LEMENTS
 
 
A Power 
Port 
 
 
Quick-connect spring-clamp terminals, connection for input voltage, 
output voltage and battery 
B  Signal Port  
 
Plug connector with screw terminals, inserted from the bottom. 
Connections for the Ready, Buffering, Replace Battery relay contacts and 
for the Inhibit input. See details in chapter 
. 
C  Green Status LED 
 Ready: 
Battery is charged > 85%, no wiring failure is recognized, input 
voltage is sufficient and inhibit signal is not active. 
 Charging: Battery is charging and the battery capacity is below 85%. 
 Buffering: Unit is in buffer mode. 
 
Flashing pattern of the green status LED: 
Ready
Charging
Buffering
ON
OFF
ON
OFF
ON
OFF
 
D  Yellow Diagnosis LED 
 Overload: 
Output has switched off due to long overload in buffer mode 
or due to high temperatures. 
 Replace 
battery: 
Indicates a battery which failed the battery quality test 
(SoH test). Battery should be replaced soon. 
 Buffer-time 
expired: 
Output has switched off due to settings of Buffer-
timer Limiter. This signal will be displayed for 15 minutes. 
 Inhibit 
active: 
Indicates that buffering is disabled due to an active inhibit 
signal. 
 
Flashing pattern of the yellow diagnosis LED: 
Overload
Replace 
Battery
Buffer time 
expired
Inhibit 
active
ON
OFF
ON
OFF
ON
OFF
ON
OFF
 
 
E  Red Check Wiring LED 
 
This LED indicates a failure in the installation (e.g. too low input voltage), wiring, battery or battery fuse.
 
F Buffer-time 
Limiter: 
 
User accessible dial which limits the maximum buffer time in a buffer event to save battery energy. When the 
battery begins to recharge after a discharging event, the process is completed much faster since only the energy 
which was taken out of the battery needs to be “refilled”. The following times can be selected: 10 seconds, 30 
seconds, 1 minute, 3 minutes, 10 minutes or infinity (until battery is flat) which allows buffering until the deep 
discharge protection stops buffering. 
G End-of-charge-voltage 
Selector: 
 
The end-of-charge-voltage shall be set manually according to the expected temperature in which the battery is 
located. The dial on the front of the unit allows an continuously adjustment between +10 and +40°C. 10°C will set 
the end-of-charge-voltage to 13.9V, 25°CÆ13.65V and 40°CÆ13.4V. If in doubt about the expected temperature, 
set the unit to 35°C.
 