Puls ML50.100 Power Supply Guia De Especificação

Página de 20
 
 
 
ML50.100, ML50.109 
 
MiniLine 
 
24V, 2.1A, S
INGLE 
P
HASE 
I
NPUT
 
 
 
Mar. 2007 / Rev. 1.0  DS-ML50.100-EN 
All parameters are specified at 24V, 2.1A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. 
www.pulspower.com   Phone +49 89 9278 0    Germany 
8/20 
 
12. F
UNCTIONAL 
D
IAGRAM
 
 
 
Fig. 12-1   Functional diagram 
 
Input Fuse
&
Input Filter
L
N
Output Over-
Voltage
Protection
DC-OK
Transistor
Signal
Input
Rectifier
&
Inrush
Limiter
Power
Converter
Output
Voltage
Regulator
+
+
-
-
Output
Filter
V
OUT
DC
ok
DC-ok
Signal
 
 
 
13. R
ELIABILITY
 
 
These units are extremely reliable and use only the highest quality materials. The number of critical components such 
as electrolytic capacitors has been reduced. 
   
AC 100V 
AC 120V 
AC 230V 
 
  Lifetime expectancy 
min. 
34 000h 
44 000h 
54 000h 
40°C, 24V, 2.1A 
   
min. 
112 000h 
117 000h 
111 000h 
40°C, 24V, 1.05A 
   
min. 
96 000h 
125 000h 
152 000h 
25°C, 24V, 2.1A 
  MTBF SN 29500, IEC 61709 
2 383 000h 
2 456 000h 
2 613 000h 
40°C, 24V, 2.1A 
   
3 977 000h 
4 100 000h 
4 362 000h 
25°C, 24V, 2.1A 
  MTBF MIL HDBK 217F 
1 021 000h 
1 053 000h 
1 120 000h 
40°C, 24V, 2.1A, Ground Benign GB40 
   
1 370 000h 
1 413 000h 
1 503 000h 
25°C, 24V, 2.1A, Ground Benign GB25 
 
The  Lifetime expectancy shown in the table indicates the operating hours (service life) and is determined by the 
lifetime expectancy of the built-in electrolytic capacitors.  
Lifetime expectancy is specified in operational hours. Lifetime expectancy is calculated according to the capacitor’s 
manufacturer specification. The prediction model allows a calculation of up to 15 years from date of shipment. 
MTBF stands for Mean Time Between Failure, which is calculated according to statistical device failures, and indicates 
reliability of a device. It is the statistical representation of the likelihood of a unit to fail and does not necessarily 
represent the life of a product.