Puls ML50.100 Power Supply Guia De Especificação

Página de 20
 
 
 
ML50.100, ML50.109 
 
MiniLine 
 
24V, 2.1A, S
INGLE 
P
HASE 
I
NPUT
 
 
 
Mar. 2007 / Rev. 1.0  DS-ML50.100-EN 
All parameters are specified at 24V, 2.1A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. 
www.pulspower.com   Phone +49 89 9278 0    Germany 
10/20 
 
16. EMC 
 
The CE mark indicates conformance with EMC guideline 89/336/EEC, 93/68/EEC and the low-voltage directive (LVD) 
73/23/EWG. A detailed EMC Report is available on request. 
 
 
EMC Immunity 
EN 61000-6-2, EN 61000-6-1   
Generic standards 
 
Electrostatic discharge  
EN 61000-4-2 
Contact discharge 
Air discharge 
8kV 
8kV 
Criterion A 
Criterion A 
  Electromagnetic RF field 
EN 61000-4-3 80MHz-1GHz 
10V/m 
Criterion 
 
Fast transients (Burst) 
EN 61000-4-4 
Input lines 
Output lines 
4kV 
2kV 
Criterion A 
Criterion A 
 
Surge voltage on input 
EN 61000-4-5 
L Æ N 
N / L Æ PE 
2kV  
4kV 
Criterion A 
Criterion A 
 
Surge voltage on output 
EN 61000-4-5 
+ Æ - 
+ / - Æ PE 
500V 
500V 
Criterion A 
Criterion A 
  Conducted disturbance 
EN 61000-4-6 
0,15-80MHz 
10V 
Criterion A 
 
Mains voltage dips 
EN 61000-4-11 
0% of 100Vac
 
40% of 100Vac 
70% of 100Vac  
0% of 200Vac
 
40% of 200Vac 
70% of 200Vac 
0Vac, 20ms 
40Vac, 200ms 
70Vac, 500ms 
0Vac, 20ms 
80Vac, 200ms 
140Vac, 500ms 
Criterion A 
Criterion C 
Criterion A 
Criterion A 
Criterion A 
Criterion A 
  Voltage interruptions 
EN 61000-4-11 
 
0Vac, 5000ms 
Criterion C 
  Input voltage swells 
PULS internal standard 
 
300Vac, 500ms 
Criterion A 
 
Powerful transients 
VDE 0160 
over entire load 
range 
750V, 1.3ms 
Criterion A 
Criterions: 
A:  Power supply shows normal operation behavior within the defined limits.  
C:  Temporary loss of function is possible. Power supply might shut-down and restarts by itself. No damages or hazards to the power 
supply will occur. 
 
  EMC Emission 
EN 61000-6-3, EN 61000-6-4 
Generic standards 
  Conducted emission  
EN 55011, EN 55022, FCC Part 15, CISPR 11, CISPR 22 
Class B, input lines 
   
EN 55022 
Class B, output lines  
  Radiated emission 
EN 55011, EN 55022 
Class B 
  Harmonic input current 
EN 61000-3-2  
Fulfilled 
  Voltage fluctuations, flicker EN 
61000-3-3 
 
Fulfilled 
 
This device complies with FCC Part 15 rules.  
Operation is subjected to the following two conditions: (1) this device may not cause harmful interference, and (2) this 
device must accept any interference received, including interference that may cause undesired operation. 
 
 
  Switching frequency 
variable, typ. 100kHz, (60-275kHz) 
Input voltage and output load dependent