Puls ML60.241 Power Supply Guia De Especificação
ML60.241
MiniLine
24V,
2.5A,
S
INGLE
P
HASE
I
NPUT
9. F
UNCTIONAL
D
IAGRAM
Fig. 9-1 Functional diagram
Input Fuse
&
Input Filter
&
Input Filter
L
N
N
Output Over-
Voltage
Protection
Input
Rectifier
&
NTC
Inrush
Limiter
Rectifier
&
NTC
Inrush
Limiter
Power
Converter
Output
Voltage
Regulator
+
-
-
-
Output
Filter
+
V
OUT
DC
on
PE
10. F
RONT
S
IDE AND
U
SER
E
LEMENTS
Fig. 10-1 Front side
A Output Terminals
Screw
terminals,
Dual terminals for the negative and positive pole. Both poles are
equal
+ Positive output
- Negative (return) output
B Input Terminals
Screw
terminals
L
Phase (Line) input
N
Neutral conductor input
PE (Protective Earth) input
C DC-on LED (green)
On, when the voltage on the output terminals is > 17V
D Output voltage potentiometer
(single turn potentiometer)
Turn to set the output voltage. Factory set: 24.5V
Turn to set the output voltage. Factory set: 24.5V
Sep. 2010 / Rev. 1.0 DS-ML60.241-EN
All parameters are specified at 24V, 2.5A, 230Vac input, 25°C ambient and after a 5 minutes run-in time unless otherwise noted.
All parameters are specified at 24V, 2.5A, 230Vac input, 25°C ambient and after a 5 minutes run-in time unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany
9/22