Puls CS10.241 Power Supply Guia De Especificação
CS10.241, CS10.241-S1
C–Series
24V, 10A, S
INGLE
P
HASE
I
NPUT
August 2006 / Rev. 1.1 DS-CS10.241-EN / All parameters are specified at 24V, 10A, 230Vac and 25°C ambient unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany
5/20
8. O
UTPUT
Output
voltage
nom.
24V
Adjustment
range
min.
24-28V guaranteed
max.
30V
at clockwise end position of potentiometer
Factory
setting
24.1V
±0.2%,
at full load, cold unit
Line
regulation
max.
70mV
90 to 132Vac or 180 to 264Vac
Load
regulation
max.
100mV
static value, 0A Æ 10A Æ 0A
Ripple and noise voltage
max.
50mVpp
20Hz to 20MHz, 50Ohm
Output
capacitance
typ.
7 000µF
Output current
nom.
12A
at 24V, ambient < 45°C, see
Fig. 8-1
nom.
10A
at 24V, ambient < 60°C, see
Fig. 8-1
nom.
10.3A
at 28V, ambient < 45°C, see
Fig. 8-1
nom.
8.6A
at 28V, ambient < 60°C, see
Fig. 8-1
Output
power
nom.
288W
ambient < 45°C
nom.
240W
ambient < 60°C
Short-circuit
current
min.
14A
load impedance 100mOhm, see
Fig. 8-1
max.
18A
load impedance 100mOhm, see
Fig. 8-1
Fig. 8-1 Output voltage vs. output current, typ.
Output Voltage
0
0
4
8
12
16
4
8
12
28V
16
20
24
20A
10
6
2
14
18
Adjustment
Range
Output Current
+60°C
+25°C
-25°C
Peak current capability (up to several ms)
The power supply can deliver a peak current which is higher than the specified short term current. This helps to start
current demanding loads or to safely operate subsequent circuit breakers.
current demanding loads or to safely operate subsequent circuit breakers.
The extra current is supplied by the output capacitors inside the power supply. During this event, the capacitors will
be discharged and causes a voltage dip on the output. Detailed curves can be found in chapter 25.1.
be discharged and causes a voltage dip on the output. Detailed curves can be found in chapter 25.1.
Peak current voltage dips
typ.
from 24V to 18.5V
at 20A for 50ms, resistive load
typ.
from 24V to 17.5V
at 50A for 2ms, resistive load
typ.
from 24V to 12V
at 50A for 5ms, resistive load