In the garage. Products of combustion are present when you start your automobile. 
• 
Less than 4” (10cm) from the peak of an “A” frame type ceiling. 
• 
In an area where the temperature may fall below 40ºF or rise above 100ºF, such as garages and unfinished attics. 
• 
In dusty areas. Dust particles may cause nuisance alarm or a failure to alarm. 
• 
In very humid areas. Moisture or steam can cause nuisance alarms. 
• 
In insect-infested areas. 
• 
Smoke alarms should not be installed within 3 ft (.9m) of the following: the door to a kitchen, the door to a bathroom 
containing a tub or shower, forced air supply ducts used for heating or cooling, ceiling paddle or whole house ventilating fans, 
or other high air flow areas. 
• 
Kitchens. Normal cooking may cause nuisance alarms. If a kitchen alarm is desired, it should have an alarm silence feature or 
be a photoelectric type. 
• 
Near fluorescent lights, amateur radios, electrical equipment or other devices known to transmit an RF signal. Electronic 
“noise” may cause nuisance alarms. 
• 
Near large metal surfaces and bundles of wire. 
 
Smoke alarms are not to be used with detector guards unless the combination (alarm and guard) have been evaluated and found 
suitable for that purpose. 
 
3.   I NS T AL L AT I O N  I NS T RUCT I O NS  
WIRELESS INTERCONNECT SETUP 
 
1. 
Remove all your new Kidde Wireless Interconnect devices from their respective packages and place them in front of you.  
DO NOT PLUG THEM IN OR INSTALL THE BATTERIES. 
2. 
Find the 8-position dipswitch located on the back of each device. For this model, the 
dipswitch is located on the back of the device (see Figure 4). 
3. 
Select one of the units.  You will define the ID of your system by positioning the 
switches of the dipswitch in a random pattern. The ID will need to be the same for 
each alarm or accessory. This ID will differentiate your alarm system from similar 
systems nearby. DO NOT USE THE DEFAULT ID YOUR UNITS ARE SHIPPED 
WITH! 
4. 
Using a pen or pencil, change the switches in each of the Kidde Wireless devices to 
match the pattern you selected in step 3. Insure that the sequence is not reversed. 
5. 
Power each unit after setting the ID by installing the batteries. The alarms read the 
ID only when they are first powered up. Any changes to the switches after the unit is 
powered will not be recognized and will require the units to be disconnected from power for a minimum of 30 seconds before 
powering the units up again. 
6. 
Push and hold the test button on each unit for at least 5 seconds or until all the alarms produce an alarm signal. If all the alarms 
do not produce an alarm signal refer to the trouble-shooting section at the end of the manual.   
CAUTION: Due to the loudness of the alarm, always stand an arms length away from the unit when testing.   
7. 
Install the alarms in accordance with the owner's manual and repeat step 6. Since Wireless communication can be interrupted 
by a number of factors, you must test your alarms weekly to ensure proper communication between alarms. 
8. 
Read the owner’s manual and keep it in a safe place for future reference. 
 
If your Wireless smoke alarms enter alarm mode, first check to see if there is a fire.  If a fire does not exist, and 
the test buttons have not been activated on any of the units, it is likely that you are receiving interference from a 
similar system nearby.  In this case, repeat the above steps and select a different dipswitch pattern, making sure 
to disconnect power and remove the batteries before changing the switch positions. 
 
A maximum of 24 devices may be interconnected in a multiple station arrangement. The interconnect system should not exceed the 
NFPA interconnect limit of 12 smoke alarms and/or 18 alarms total (smoke, heat, carbon monoxide, etc.).  With 18 alarms 
interconnected, it is still possible to interconnect up to a total of 6 remote signaling devices and/or relay modules. 
 
Kidde WIRELESS Battery-powered alarms CAN ONLY BE interconnected with other Kidde WIRELESS alarms and 
accessories. Refer to User’s Guide supplied with each Kidde product for lists of interconnect compatible models, 
brands, and devices
 
 
BATTERY INSTALLATION 
 
Batteries were not installed at the factory and must be installed for the unit to operate! 
Install the three(3) AA batteries in the back of the alarm. 
• 
The mounting plate must be removed from the back of the unit to install batteries. To remove, hold the mounting plate 
and twist counterclockwise (left).
 
• 
The battery polarity markings on the bottom of the battery compartment must be adhered to. 
• 
Batteries must be installed in the sequence shown (see Figure 5). If batteries seem difficult to install, they’re not being 
installed in the proper sequence. 
• 
Alarm will not engage to bracket unless all three batteries are installed. 
 
Removal of any or all batteries will render the alarm inoperative!
 