Walter Kidde Portable Equipment Inc. 9000162 Manual Do Utilizador

Página de 9
 
 
Figure 7A & 7B 
 
4.   O P E RAT I O N  AND  T E S T I NG  
OPERATION 
The smoke alarm is operating once fresh batteries are installed and testing is complete. When the smoke alarm ionization chamber 
senses products of combustion, the horn will sound a loud (85db) temporal alarm until the sensing chamber is cleared of smoke 
particles.  
 
Smart HUSH
TM
 CONTROL: The Smart HUSH
TM
 feature has the capability of temporarily desensitizing the smoke sensing circuitry 
for approximately 7 minutes to quiet your alarm while taking care of a non-emergency event. This feature is to be used only when a 
known alarm condition, such as smoke from cooking, activates the alarm. The smoke alarm is desensitized by pushing the Smart 
HUSH
TM
 button on the smoke alarm cover. If the smoke is not too dense, the alarm will silence immediately and the green LED will 
blink every 2 seconds for approximately 7 minutes. This indicates that the alarm is in a temporarily desensitized condition. The smoke 
alarm will automatically reset after approximately 7 minutes and sound the alarm if particles of combustion are still present. The 
Smart HUSH
TM
 feature can be used repeatedly until the air has been cleared of the condition causing the alarm. Pushing the test button 
on the alarm will end the Hush period. 
 
Remote HUSH: Press the button on any wireless device to activate the Smart Hush® on a wireless smoke alarm that is initiating an 
alarm. This allows you to enable the Smart HUSH™ feature on a Kidde Wireless smoke alarm that may be installed in an area that is 
difficult to reach. This feature should only be used when a known alarm condition, such as smoke from cooking, activates the alarm. 
 
Low Battery Hush: When the batteries need to be replaced, the unit will produce a low battery “chirp” once per minute.  The Low 
Battery HUSH allows you to press the button on the alarm producing the warning and disable the “chirp” for up to 12 hours. This 
gives you a chance to replace the battery at a more convenient time without sacrificing your safety by disconnecting the alarm from 
power. During this Low Battery HUSH period your alarm is performing normally and is not desensitized.  
 
 
NOTE: DENSE SMOKE WILL OVERRIDE THE HUSH
®
 CONTROL FEATURE AND SOUND A CONTINUOUS 
ALARM. 
 
CAUTION: BEFORE USING THE ALARM HUSH
®
 FEATURE, IDENTIFY THE SOURCE OF THE 
SMOKE AND BE CERTAIN A SAFE CONDITION EXISTS. 
 
LED Indicator Operation 
Red LED: 
The red LED will flash in conjunction with the alarm beep. Therefore, the red LED will flash during a smoke alarm, a low battery 
mode chirp and a unit error mode chirp. 
Green LED: 
The green LED will illuminate as described below under the following conditions: 
STANDBY CONDITION - The LED will flash approximately every 10 seconds. 
INITIATING ALARM INDICATOR The LED will flash every second while sounding an alarm to signify that the alarm 
sensed a smoke hazard. This will only be displayed on the alarms that sensed smoke. The remaining interconnected