Opticon Sensors Europe BV PX20 Manual Do Utilizador

Página de 27
13
 
Opticon
 
PX-20
 
Specifications Manual
 
 
 
 
 
 
 
8.2.  Scan Area and Depth of Field 
The scan area is measured from the front edge of the camera module. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
50  
100  
150  
200  
250  
300 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Code 39 
0.127(5mil) 
90  
130 
 
0.254(10mil) 
70  
210 
 
 
[ Unit 
: mm ] 
 
0.508(20mil) 
65  
300 
 
 
 
Code 128 
 
 
 
UPC 100% 
0.20(7.9mil) 
80  
190 
 
 
0.33(13mil) 
55  
225 
 
 
 
 
PDF417 
0.169(6.7mil) 
85 
 
0.254(10mil) 
65 
 
145 
 
 
 
 
200 
 
 
 
 
QR Code 
 
 
 
 
Data Matrix 
0.212(8.4mil) 
95  
120 
 
0.381(15mil) 
60  
200 
 
 
0.254(10mil) 
80  
150 
 
 
Note: The depth of field depends on the view angle and symbol length