Opticon Sensors Europe BV PX20 Manual Do Utilizador

Página de 27
14
 
Opticon
 
PX-20
 
Specifications Manual
 
 
 
MRD 
: 32% and higher 
(70% or higher reflectivity of space and quiet zone) 
Distance 
: 130 mm from the front edge of the camera module 
Bar Code Sample 
: UPC specified in Chapter 8. (Resolution: 0.33 mm, PCS: 0.3) 
 
Bar Code Sample 
: The above codes specified in Chapter 8 
Distance 
: 100 mm from the front edge of the camera module 
Angle 
α = 0°, β =+15°, γ = 0° 
Curvature 
: R 
= ∞ 
For the pitch angle and tilt angle measurement, set the skew angle 
β = +15° 
 
Bar Code Sample 
: 0.20 mm Code 39  specified in Chapter 8 
Distance 
: 160 mm from the front edge of the camera module 
Angle 
α = 0°, β =+15°, γ = 0° 
Curvature 
: R 
= ∞ 
 
 
 
 
 
Figure 3: Scan Area and Depth of Field 
 
8.3.  Print Contrast Signal 
PSC 0.3 or higher 
 
<Conditions> 
 
 
 
 
 
 
MRD = Minimum reflectance of white bar - Maximum reflectance of black bar 
 
PCS =   
Error! 
 
 
 
8.4.  Minimum Resolution 
1D Code 
: 0.127 mm (5 mil) 
Code 39 specified in Chapter 8 
GS1-Databar 
: 0.169 mm (6.7 mil) 
GS1 Databar-Limited specified in Chapter 8 
Stacked Code   : 0.169 mm (6.7 mil) 
PDF417, GS1 Databar-Limited Composite specified in Chapter 8 
2D Code 
: 0.212 mm (8.4 mil) 
OR Code and Data Matrix specified in Chapter 8 
 
<Conditions> 
 
 
 
 
 
 
 
 
8.5.  Wide Bar Code 
Code 39 with width of 100 mm and resolution of 0.2 mm can be read. 
 
<Conditions> 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Figure 4: Wide Bar Code