Opticon Sensors Europe BV PX20 Manual Do Utilizador

Página de 27
15
 
Opticon
 
PX-20
 
Specifications Manual
 
 
 
Ambient Temperature and Humidity 
: Room temperature and Room humidity 
Ambient Light 
: 500 lux to 1000 lux (on the surface of a bar code) 
Distance 
: 130 mm from the front edge of the camera module 
Angles 
α= 0° 
Skew 
β = 15° 
Tilt 
γ = 0° 
Curvature 
: R 
= ∞ 
Power Supply Voltage 
: 3.3 and 5.0 V 
PCS (1D and 2D) 
: 0.9 or higher 
Bar Code Sample 
: UPC with 0.33 mm resolution specified in Chapter 8 
 
 
 
 
 
8.6.  Motion Tolerance 
UPC bar code 100% can be read when it is moving at 2m/s. 
 
<Conditions> 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Figure 5: Motion Tolerance 
 
Note: The above shows the possible speed of reading, but no guarantee of 100% reading. 
: Scanning may fail due to the specular reflection of illumination LEDs when the reflectivity is high.