Lightning Protection Unit (LPU)
Site Installation
The LPU has two cable glands on the bottom for CAT‐5e/6 cables, in addition to a grounding 
lug. There is an extra hole for a second screw when installed on a wall. On the side of the LPU 
is a slot for the metal tie when installed on a pole, as shown in 
 and 
: 
To install an LPU on a pole:
1.  Choose a location as close as possible to the radio unit. 
2. Insert the metal tie through the slots as shown in 
. Make sure the LPU is 
oriented in the correct direction, as shown in 
. 
Figure 2‐57: LPU attached to pole with metal tie
3. Tighten the metal tie.
4. Connect the grounding lug to a grounding source. 
5. Remove the cable glands. 
6. Thread the CAT‐5e/6 cables through the cable glands, and connect the cables to the 
LPU as shown in 
Figure 2‐55: LPU: Bottom View
Figure 2‐56: LPU: Side View